APC Smart-UPS VT 20kVA 400V w/3 Batt Mod Exp to 4, Start-Up 5X8, Int Maint Bypass, Parallel Capable

Cod Produs: APSUVTP20KH3B4S Categorie:

APC Smart-UPS VT, 16 kW / 20 kVA,Input 400V 3PH / Output 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model. Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Start up included, User Manual. - Parallel-capacity capable Increases total power capacity by using multiple UPSs simultaneously. - Parallel-redundant capable Power the connected equipment with multiple UPSs to increase system redundancy Availability - Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources. - Scalable runtime Allows additional run time to be quickly added as needed. - Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. - Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. - Battery modules connected in parallel Delivers higher availability through redundant batteries. Serviceability - User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) - Battery replacement without tools Allows quick, easy battery replacement. - Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Shippable with modules installed Enables pre-installation UPS staging and testing and faster installation. - Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Manageability - Network manageable Provides remote management of the UPS over the network. - InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager. - LCD display Alpha-Numeric Display which displays system parameters and alarms. - Audible alarms Provides notification of changing utility power and UPS conditions. - Programmable frequency Ensures compatibility with different input frequencies. - LED status indicators Quickly understand unit and power status with visual indicators. - SmartSlot Customize UPS capabilities with management cards. Total Cost of Ownership - Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. - Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. - Manual maintenance bypass Reduces installation costs by eliminating the need for an external mechanical bypass. - Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Protection - Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. - Cold-start capable Provides temporary battery power when the utility power is out.

Additional information

Battery type

APC Smart-UPS VT, 16 kW / 20 kVA,Input 400V 3PH / Output 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model.

Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Start up included, User Manual.

– Parallel-capacity capable
Increases total power capacity by using multiple UPSs simultaneously.
– Parallel-redundant capable
Power the connected equipment with multiple UPSs to increase system redundancy

Availability
– Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
– Scalable runtime
Allows additional run time to be quickly added as needed.
– Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
– Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
– Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
– Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Serviceability
– User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
– Battery replacement without tools
Allows quick, easy battery replacement.
– Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
– Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.
– Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Manageability
– Network manageable
Provides remote management of the UPS over the network.
– InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
– LCD display
Alpha-Numeric Display which displays system parameters and alarms.
– Audible alarms
Provides notification of changing utility power and UPS conditions.
– Programmable frequency
Ensures compatibility with different input frequencies.
– LED status indicators
Quickly understand unit and power status with visual indicators.
– SmartSlot
Customize UPS capabilities with management cards.

Total Cost of Ownership
– Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
– Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
– Manual maintenance bypass
Reduces installation costs by eliminating the need for an external mechanical bypass.
– Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Protection
– Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
– Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
– Cold-start capable
Provides temporary battery power when the utility power is out.